DIGI RPM

title1_cinfo_btnl_2
cscenter_btnl

Terminal server

Introduction of major products of BuRim Co., Ltd.

Terminal server

Introduction of major products of BuRim Co., Ltd.

DIGI RPM

Remote power control system and Digi Remote Power Manager (Digi RPM) series are connected to Digi CM. It is the device that can enhance the flexible control of equipment through turning ON/OFF and through measuring current/ voltage of the power of devices connected to the CM.


· Product Features

Support console access and power control by linking console service and Digi CM series
Eight port type (1U horizontal installation type) and ten port type power socket (0U vertical installation type)
Support maximum of 16A for the whole capacity of power control
Support maximum of 10A per 1 port of power output capacity
Support maximum of 16 connections due to RS232 connection of daisy-chain method.
RMS current and voltage, inspection of internal temperature and LCD display
Alarm goes on and the circuit break is shut off in the case of over current
Support name registration for each port
Support periodic power on/off and recycling


· Specification

8-port 1U rack-mountable and 10-port 0U rackmountable models
120VAC, 20A and 240VAC, 16A models (up to 10A per port)
Front panel LCD for direct viewing of total current load and power consumption
Two RJ 45 serial ports (one for communications, one for daisy-chaining)
Power sensor
- Average/apparent power
- RMS voltage/current
- Circuit breaker status
- Max current
Integrated temperature sensor
Integrated with user interface of Digi CM™ and PortServer® TS products
Cascading allows up to ten Digi RPMs to be daisy-chained to a single Digi CM serial port
Alarm LED for high current alert
Command line interface for direct serial connection
Ships with cables required to connect to Digi CM, PortServer TS, or PC serial port
Status indicator LEDs for outlet status and alarm indication

Operating temperature: 5º C to 50º C (41º F to 122º F)
Relative humidity: 5% to 90% (non-condensing)
Storage temperature: -40º C to +85º C (-40º F to +185º F)

UL 1950, EN60950
FCC Part 15, A
FCC Part 15, A
EN55022, A
EN55024
CE

120VAC model
Outlet type: NEMA 5-15 R
Max current: 10A
240VAC model
Outlet type: IEC 60320 C13R
Max current: 10A

120VAC model
Plug type: IEC 60320 C20 (NEMA 2-20P) suitable for 20A circuits
Max current rating: 16A
240VAC model
Plug type: CEE 7/7 suitable for 16A circuits
Max current rating: 16A


DIGI RPM

Remote power control system and Digi Remote Power Manager (Digi RPM) series are connected to Digi CM. It is the device that can enhance the flexible control of equipment through turning ON/OFF and through measuring current/ voltage of the power of devices connected to the CM.

· Product Features

Support console access and power control by linking console service and Digi CM series
Eight port type (1U horizontal installation type) and ten port type power socket (0U vertical installation type)
Support maximum of 16A for the whole capacity of power control
Support maximum of 10A per 1 port of power output capacity
Support maximum of 16 connections due to RS232 connection of daisy-chain method.
RMS current and voltage, inspection of internal temperature and LCD display
Alarm goes on and the circuit break is shut off in the case of over current
Support name registration for each port
Support periodic power on/off and recycling

· Specification

8-port 1U rack-mountable and 10-port 0U rackmountable models
120VAC, 20A and 240VAC, 16A models (up to 10A per port)
Front panel LCD for direct viewing of total current load and power consumption
Two RJ 45 serial ports (one for communications, one for daisy-chaining)
Power sensor
- Average/apparent power
- RMS voltage/current
- Circuit breaker status
- Max current
Integrated temperature sensor
Integrated with user interface of Digi CM™ and PortServer® TS products
Cascading allows up to ten Digi RPMs to be daisy-chained to a single Digi CM serial port
Alarm LED for high current alert
Command line interface for direct serial connection
Ships with cables required to connect to Digi CM, PortServer TS, or PC serial port
Status indicator LEDs for outlet status and alarm indication

Operating temperature: 5º C to 50º C (41º F to 122º F)
Relative humidity: 5% to 90% (non-condensing)
Storage temperature: -40º C to +85º C (-40º F to +185º F)

UL 1950, EN60950
FCC Part 15, A
FCC Part 15, A
EN55022, A
EN55024
CE

120VAC model
Outlet type: NEMA 5-15 R
Max current: 10A
240VAC model
Outlet type: IEC 60320 C13R
Max current: 10A

120VAC model
Plug type: IEC 60320 C20 (NEMA 2-20P) suitable for 20A circuits
Max current rating: 16A
240VAC model
Plug type: CEE 7/7 suitable for 16A circuits
Max current rating: 16A


Previous Next